Nullam dignissim, ante scelerisque the is euismod fermentum odio sem semper the is erat, a feugiat leo urna eget eros. Duis Aenean a imperdiet risus.

ME21424

ME21424

Test Module

A patented PP modular BDD electrolyzer holding two MU724 module units — 0.84 m² active anode area, for pilot tests or series/parallel scaling into large-scale wastewater treatment.

Product Description

The ME21424 is a patented PP modular BDD electrolyzer — a sealed electro-oxidation cell fully compatible with the MU-series modules. Holding two MU724 module units, it delivers 0.84 m² of active anode area and scales from single-unit pilot tests to large-scale engineering operation.

At a Glance
0.84 m²Active anode area — 2× MU724 module units
10 m³/hInfluent flow rate
73 kgNet weight — 930 × 350 × 535 mm
≤230 AWorking DC current — DC 300A/20V rectifier

What Is the ME21424?

Boromond’s patented modular electrolyzer is integrally molded from high-quality PP material, featuring solid structure and full compatibility with MU-series modules. It creates a sealed electrolysis environment for efficient water treatment. The ME21424 supports up to two MU724 modular units, composing the ME series BDD electrolysis equipment. It meets diverse treatment demands through adjustable working areas. As a core model for large-scale wastewater treatment, it delivers flexible deployment — a single unit is available for pilot tests, while multiple units in series or parallel can be scaled for large-scale engineering operation. The system enables quick construction and flexible capacity expansion with water-volume changes. Seamless connection to existing processes requires no major modifications. Balancing experimental verification and engineering application, the ME21424 is an optimal choice for wastewater treatment from pilot research to mass-scale projects.

Main Performance Parameters

Nameplate & Housing

Product Model ME21424
Dimension (L × W × H) 930 × 350 × 535 mm
Net Weight 73 kg
Module Unit Model MU724
Number of Module 2
Installation Indoor
Port Flange DN50, PN10

Electrode & Performance

Anode BDD (Boron-Doped Diamond)
Cathode Titanium
Active Anode Area 0.84 m²
Anode Current Density ≤55 mA/cm²
Working DC Current ≤230 A
Working DC Voltage ≤20 V
Max Heating Power 2.2 kW
DC Rectifier DC 300A / 20V

Operating & Flow

Influent Flow Rate 10 m³/h
Installed Power 6 kW
Power Consumption (single module @ 7.5 V) ≤3.5 kW
Room Temperature 0℃ ~ 40℃
Relative Humidity ≤90%
Treatment Capacity Depends on Water Quality
Treatment Time Depends on Water Quality

Product Advantages

1

Patented PP Modular Design

Integrally molded from high-quality PP material, with a solid structure and full compatibility with MU-series modules.
2

Two MU724 Module Units

Holds up to two MU724 modular units for a 0.84 m² active anode area in a sealed electrolysis environment.
3

Pilot to Full-Scale

A single unit for pilot tests; multiple units in series or parallel scale up for large-scale engineering operation.
4

Seamless Integration

Connects to existing processes without major modifications, with quick construction and flexible capacity expansion.

Application Scenarios

  • Single-unit pilot tests
  • Multiple units in series or parallel for large-scale engineering
  • Retrofit into existing wastewater treatment systems
  • Treatment from pilot research to mass-scale projects

Frequently Asked Questions

Q1How does the ME21424 relate to the MU-series modules?+
The ME21424 is the electrolyzer housing: a sealed PP vessel that holds Boromond’s MU-series module units. It is integrally molded from PP and fully compatible with the MU724, MU924 and MU1124 module units — the ME21424 configuration holds two MU724 units.
Q2How many MU724 module units does a single ME21424 hold?+
A single ME21424 supports two MU724 module units, delivering a total active anode area of 0.84 m² with BDD anodes and titanium cathodes.
Q3Can the ME21424 scale from pilot testing to full-scale operation?+
Yes. A single unit is available for pilot tests, while multiple units can be connected in series or parallel and scaled for large-scale engineering operation — balancing experimental verification and engineering application.
Q4How does the ME21424 differ from the ME21824 and ME22224?+
All three share the same 930 × 350 × 535 mm enclosure, but pair it with different module units: the ME21424 uses two MU724 units (0.84 m², 73 kg, DC 300A/20V rectifier), the ME21824 uses two MU924 units (1.06 m², 80 kg, DC 400A/20V), and the ME22224 uses two MU1124 units (1.30 m², 87 kg, DC 400A/20V).
Q5What flow rate and power supply should I prepare for?+
Plan for a 10 m³/h influent flow rate and an installed power of 6 kW. The electrolyzer runs on a DC 300A/20V rectifier with a working DC current of ≤230 A and voltage of ≤20 V, indoors at 0℃~40℃ and ≤90% relative humidity.